<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article article-type="research-article" dtd-version="1.1" specific-use="sps-1.9" xml:lang="en" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
	<front>
		<journal-meta>
			<journal-id journal-id-type="publisher-id">rbz</journal-id>
			<journal-title-group>
				<journal-title>Revista Brasileira de Zootecnia</journal-title>
				<abbrev-journal-title abbrev-type="publisher">R. Bras. Zootec.</abbrev-journal-title>
			</journal-title-group>
			<issn pub-type="ppub">1516-3598</issn>
			<issn pub-type="epub">1806-9290</issn>
			<publisher>
				<publisher-name>Sociedade Brasileira de Zootecnia</publisher-name>
			</publisher>
		</journal-meta>
		<article-meta>
			<article-id pub-id-type="other">03001</article-id>
			<article-id pub-id-type="doi">10.37496/rbz5520250130</article-id>
			<article-categories>
				<subj-group subj-group-type="heading">
					<subject>Precision livestock</subject>
				</subj-group>
			</article-categories>
			<title-group>
				<article-title>Colorimetric analysis of phosphorus concentration in animal feeds using images from smartphone or scanner – a proof-of-concept study</article-title>
			</title-group>
			<contrib-group>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0009-0008-3298-6683</contrib-id>
					<name>
						<surname>Mattos</surname>
						<given-names>Suellen Sobrinho França</given-names>
					</name>
					<role>Data curation</role>
					<role>Formal analysis</role>
					<role>Investigation</role>
					<role>Writing – original draft</role>
					<role>Writing – review &amp; editing</role>
					<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
				</contrib>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0009-0007-2332-7419</contrib-id>
					<name>
						<surname>Silva</surname>
						<given-names>Crysthal Gonçalves da</given-names>
					</name>
					<role>Investigation</role>
					<role>Writing – review &amp; editing</role>
					<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
				</contrib>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0001-5473-5924</contrib-id>
					<name>
						<surname>Lima</surname>
						<given-names>Lorhaine Bernardes de</given-names>
					</name>
					<role>Investigation</role>
					<role>Writing – review &amp; editing</role>
					<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
				</contrib>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0002-1356-154X</contrib-id>
					<name>
						<surname>Maia</surname>
						<given-names>Laryssa Rodrigues</given-names>
					</name>
					<role>Investigation</role>
					<role>Writing – review &amp; editing</role>
					<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
				</contrib>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0002-9681-4775</contrib-id>
					<name>
						<surname>Dilelis</surname>
						<given-names>Felipe</given-names>
					</name>
					<role>Conceptualization</role>
					<role>Writing – review &amp; editing</role>
					<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
				</contrib>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0001-8676-5888</contrib-id>
					<name>
						<surname>Silva</surname>
						<given-names>Tadeu Eder da</given-names>
					</name>
					<role>Writing – review &amp; editing</role>
					<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
				</contrib>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0001-6811-052X</contrib-id>
					<name>
						<surname>Martinho</surname>
						<given-names>Plinio de Freitas</given-names>
					</name>
					<role>Writing – review &amp; editing</role>
					<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
				</contrib>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0003-2152-8739</contrib-id>
					<name>
						<surname>Rufino</surname>
						<given-names>Luana Marta de Almeida</given-names>
					</name>
					<role>Project administration</role>
					<role>Resources</role>
					<role>Writing – review &amp; editing</role>
					<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
				</contrib>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0003-1140-1259</contrib-id>
					<name>
						<surname>Rodrigues</surname>
						<given-names>João Paulo Pacheco</given-names>
					</name>
					<role>Conceptualization</role>
					<role>Data curation</role>
					<role>Formal analysis</role>
					<role>Funding acquisition</role>
					<role>Investigation</role>
					<role>Project administration</role>
					<role>Resources</role>
					<role>Writing – original draft</role>
					<role>Writing – review &amp; editing</role>
					<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
					<xref ref-type="aff" rid="aff4"><sup>4</sup></xref>
					<xref ref-type="corresp" rid="c01"><sup>*</sup></xref>
				</contrib>
			</contrib-group>
			<aff id="aff1">
				<label>1</label>
				<institution content-type="orgname">Universidade Federal Rural do Rio de Janeiro</institution>
				<addr-line>
					<named-content content-type="city">Seropédica</named-content>
					<named-content content-type="state">RJ</named-content>
				</addr-line>
				<country country="BR">Brasil</country>
				<institution content-type="original"> Universidade Federal Rural do Rio de Janeiro, Seropédica, RJ, Brasil.</institution>
			</aff>
			<aff id="aff2">
				<label>2</label>
				<institution content-type="orgname">Universidade de São Paulo</institution>
				<institution content-type="orgdiv1">Escola Superior de Agricultura Luiz de Queiroz</institution>
				<addr-line>
					<named-content content-type="city">Piracicaba</named-content>
					<named-content content-type="state">SP</named-content>
				</addr-line>
				<country country="BR">Brasil</country>
				<institution content-type="original"> Universidade de São Paulo, Escola Superior de Agricultura Luiz de Queiroz, Piracicaba, SP, Brasil.</institution>
			</aff>
			<aff id="aff3">
				<label>3</label>
				<institution content-type="orgname">University of Vermont</institution>
				<addr-line>
					<named-content content-type="city">Burlington</named-content>
				</addr-line>
				<country country="US">USA</country>
				<institution content-type="original"> University of Vermont, Burlington, USA.</institution>
			</aff>
			<aff id="aff4">
				<label>4</label>
				<institution content-type="orgname">Embrapa Gado de Leite</institution>
				<addr-line>
					<named-content content-type="city">Juiz de Fora</named-content>
					<named-content content-type="state">MG</named-content>
				</addr-line>
				<country country="BR">Brasil</country>
				<institution content-type="original"> Embrapa Gado de Leite, Juiz de Fora, MG, Brasil.</institution>
			</aff>
			<author-notes>
				<corresp id="c01">
					<label>*Corresponding author:</label>
					<email>joaopaulo.rodrigues@embrapa.br</email>
				</corresp>
				<fn fn-type="edited-by">
					<label>Editors:</label>
					<p>Anderson Antonio Carvalho Alves</p>
					<p>Luan Sousa dos Santos</p>
				</fn>
				<fn fn-type="coi-statement">
					<label>Conflict of interest:</label>
					<p>The authors declare no conflict of interest.</p>
				</fn>
			</author-notes>
			<pub-date date-type="pub" publication-format="electronic">
				<day>22</day>
				<month>06</month>
				<year>2026</year>
			</pub-date>
			<pub-date date-type="collection" publication-format="electronic">
				<year>2026</year>
			</pub-date>
			<volume>55</volume>
			<elocation-id>e20250130</elocation-id>
			<history>
				<date date-type="received">
					<day>8</day>
					<month>07</month>
					<year>2025</year>
				</date>
				<date date-type="accepted">
					<day>18</day>
					<month>12</month>
					<year>2025</year>
				</date>
			</history>
			<permissions>
				<license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/" xml:lang="en">
					<license-p>This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
				</license>
			</permissions>
			<abstract>
				<title>ABSTRACT</title>
				<p>This study aimed to evaluate the potential of using images taken with a smartphone or scanner as alternatives to conventional spectrophotometry for phosphorus (P) analysis of feedstuff. Twenty-four samples of feed ingredients and commercial concentrates were evaluated. After acid digestion and dilution, the solutions were analyzed using the P-molybdate colorimetric reaction. Standards ranged from 0 to 1.4 mg L<sup>−1</sup> at intervals of 0.2 mg L<sup>−1</sup> of P in the reading solution. Standards and reading solutions were analyzed in ELISA microplates. The absorbance values of each cuvette were obtained using a spectrophotometer, and smartphone and scanner images were obtained sequentially. The images were segmented, and a circle was sampled in each cuvette to obtain the mean values of the red, green, and blue (RGB) channels. The P concentration was determined using linear regression of absorbance or the mean values obtained in the RGB channels as a function of P concentration. The repeatability (REP), limits of detection (LOD), and limits of quantification (LOQ) were calculated. Except for the scanner’s blue channel (P&lt;0.10), image-based colorimetric methods provided similar P concentrations similar to those obtained by spectrophotometry (P&gt;0.10). Using absorbance, the REP, LOD, and LOQ were 0.96%, 0.013, and 0.039 mg L<sup>−1</sup>, respectively. The best-performing image-based predictors were red and green channels of the smartphone, with REP, LOD, and LOQ values of 1.80%, 0.050, 0.150 mg L<sup>−1</sup> and 2.11%, 0.074 and 0.223 mg L<sup>−1</sup>, respectively. The smartphone red channel spectrophotometric absorbance provided equivalent P concentrations at a 99% confidence interval. Smartphone images performed better than scanner images. The use of the mean red channel from smartphone images proved promising for determining P concentration in feeds.</p>
			</abstract>
			<kwd-group xml:lang="en">
				<title>Keywords:</title>
				<kwd>absorbance</kwd>
				<kwd>feed analysis</kwd>
				<kwd>molybdenum blue</kwd>
				<kwd>RGB</kwd>
			</kwd-group>
			<funding-group>
				<award-group>
					<funding-source>PROPPG/UFRRJ</funding-source>
					<award-id>23083.046986/2023-91</award-id>
				</award-group>
				<award-group>
					<funding-source>CNPq</funding-source>
					<award-id>312920/2023-7</award-id>
				</award-group>
				<award-group>
					<funding-source>FAPERJ</funding-source>
					<award-id>200.124/2023</award-id>
				</award-group>
				<funding-statement>Financial support: This research received financial support from PROPPG/UFRRJ (23083.046986/2023-91), Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq; 312920/2023-7), and Fundação Carlos Chagas Filho de Amparo à Pesquisa do Estado do Rio de Janeiro (FAPERJ; 200.124/2023). Scholarships from Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) and PROPPG/UFRRJ were awarded to Lima, L. B. and Silva, C. G., respectively.</funding-statement>
			</funding-group>
			<counts>
				<fig-count count="3"/>
				<table-count count="1"/>
				<equation-count count="7"/>
				<ref-count count="25"/>
			</counts>
		</article-meta>
	</front>
	<body>
		<sec sec-type="intro">
			<title>1. Introduction</title>
			<p>Phosphorus (P) is an essential mineral involved in various physiological and biochemical functions in animal metabolism. It is essential for body structure and function, such the regulation of osmotic and acid-base balance by phosphate, energy use, and membrane, DNA, and RNA structures (<xref ref-type="bibr" rid="B21">Suttle, 2010</xref>). Phosphorus also plays a significant role in the global use of agricultural inputs and is closely related to several major economic and environmental concerns in animal production (Thomas Sims et al., 2005). Therefore, the proper quantification of P concentration in animal feeds is a key point for diet formulation, with attention to animal performance, health, environmental impact, and economic profitability.</p>
			<p>Standard methods for quantifying P in animal feeds are mostly based on previous mineralization by dry or wet acid digestion, with subsequent quantification of P in the resulting mineral solutions using highly instrumented or colorimetric methods. More sophisticated instruments, such as inductively coupled plasma (ICP) with optical emission spectrometry (ICP-OES) or atomic emission spectrometry (ICP-AES), are highly sensitive and precise; however, they have high acquisition and operational costs, making them inaccessible to several feed analysis laboratories. Techniques with lower costs derived from colorimetric quantification of phosphate using the molybdenum blue complex are widely used for feeds (<xref ref-type="bibr" rid="B11">Fiske and Subbarow, 1925</xref>; <xref ref-type="bibr" rid="B18">Pulliainen and Wallin, 1996</xref>; <xref ref-type="bibr" rid="B8">Detmann et al., 2025</xref>). Although relatively more accessible, the molybdenum blue method still requires a spectrophotometer to measure absorbance. The use of a spectrophotometer requires trained personnel, standardized electrical installations, and adequate facilities dedicated to the equipment. In addition, advances in lower-cost and portable instruments for colorimetric analysis may support the development of future rapid analytical methods.</p>
			<p>Studies evaluating and demonstrating the potential replacement of conventional colorimetry and spectrophotometry with image analysis using smartphones or scanners have been conducted for ammonia, sulfide, eugenol, nitrite, and ethanol analysis in different sample matrices such as water and drinks (<xref ref-type="bibr" rid="B5">Colzani et al., 2017</xref>; <xref ref-type="bibr" rid="B6">Curbani et al., 2020</xref>; <xref ref-type="bibr" rid="B10">Filgueiras et al., 2022</xref>; <xref ref-type="bibr" rid="B19">Santos et al., 2023</xref>; <xref ref-type="bibr" rid="B23">Vargas-Muñoz et al., 2023</xref>). The quantification of P by combining colorimetry and image analysis using the molybdenum blue complex has been reported for water and soil analysis (<xref ref-type="bibr" rid="B25">Yang et al., 2007</xref>; <xref ref-type="bibr" rid="B16">Moonrungsee et al., 2015</xref>; <xref ref-type="bibr" rid="B7">de Souza et al., 2023</xref>). However, the application of this technology in animal feed, associated with different image acquisition methods, has not yet been demonstrated.</p>
			<p>Thus, this study aimed to evaluate the feasibility of quantifying P in animal feeds using images obtained with accessible devices, such as smartphones or scanners, compared with traditional spectrophotometry using the molybdenum blue colorimetric method.</p>
		</sec>
		<sec sec-type="materials|methods">
			<title>2. Material and methods</title>
			<sec>
				<title>2.1. Samples</title>
				<p>A total of 24 animal feed samples were evaluated, including cereal grains and by-products such as ground maize, whole-plant corn, corn bran, corn gluten (<italic>Zea mays</italic>), wheat flour, wheat gluten (<italic>Triticum aestivum</italic> L.), oat flour (<italic>Avena sativa</italic>), potato starch (<italic>Solanum tuberosum</italic>), and tapioca granules (<italic>Manihot esculenta</italic>). The protein and oilseed sources comprised soybean meal (<italic>Glycine max</italic> L., two samples), linseed flour and linseed seeds (<italic>Linum usitatissimum</italic>), coconut flour (<italic>Cocos nucifera</italic>), and brewery wet residue (<italic>Hordeum vulgare</italic>). Other plant-derived ingredients included beet pulp (<italic>Beta vulgaris</italic> L.), eggplant flour (<italic>Solanum melongena</italic>), and cassava flour (<italic>Manihot esculenta</italic>; two samples). Additionally, commercial products were analyzed, namely rice flour (Prozyn, Butantã, SP), horse feed (Guabi Equitage, Além Paraíba, MG), cattle feed and calf feed (Ideal Rações, Rio Pomba, MG), and swine feed (Granfino, Nova Iguaçu, RJ). This diverse sampling provided a broad representation of the typical components used in animal diets, ensuring a robust evaluation across different feed matrices.</p>
			</sec>
			<sec>
				<title>2.2. Preparation of mineral solutions</title>
				<p>In all procedures, a single batch of distilled water from a 10 L Pilsen distiller (Marte Científica, Santa Rita do Sapucaí, Brazil) was used.</p>
				<p>Mineral solutions were prepared by acid digestion, as described by <xref ref-type="bibr" rid="B17">Palma et al. (2015)</xref>. Briefly, the mineral solutions were digested with 5 mL of nitric acid (65% P.A., CAS 7697-37-2, Neon Química, Suzano, Brazil) and perchloric (70% CAS 7601-090-3, Sigma-Aldrich, Burlington, USA) in a 4:1 v v<sup>1</sup> ratio, at 200 °C the solution became translucent and no brown vapors were produced. After digestion, the residues were filtered using quantitative filter paper (MN 640, Macherey-Nagel, Düren, Germany) and diluted in 50 mL volumetric flasks, which were completed with distilled water. The mineral solution was stored in polyethylene flasks and kept refrigerated (2-4 °C) until analysis.</p>
			</sec>
			<sec>
				<title>2.3. Colorimetric reaction</title>
				<p>The quantification of P was based on the phosphorus-molybdate colorimetric reaction (<xref ref-type="bibr" rid="B11">Fiske and Subbarow, 1925</xref>), as described by <xref ref-type="bibr" rid="B8">Detmann et al. (2025)</xref>. The acid solution of molybdate was composed of 20 g L<sup>1</sup> of ammonium molybdate (P.A., CAS 12054-85-2, Dinâmica Química, Indaiatuba, Brazil), 1 g L<sup>1</sup> of bismuth carbonate (P.A., CAS 5892-10-4, Dinâmica Química, Indaiatuba, Brazil), and 253.9 g L<sup>1</sup> of sulfuric acid (P.A., CAS 7664-93-4, Dinâmica Química, Indaiatuba, Brazil). For each analytical round, a 40 g L<sup>1</sup> solution of ascorbic acid (P.A., CAS 50-81-7, Dinâmica Química, Indaiatuba, Brazil) was prepared and used within 60 minutes after preparation. A stock solution of 4.39 g L<sup>1</sup> of monobasic potassium phosphate (P.A., CAS 7778-77-0, Dinâmica Química, Indaiatuba, Brazil) was diluted at 1:100 v v<sup>1</sup> to prepare the standard solution.</p>
				<p>The reading solutions were prepared in 50 mL flasks, to which 5 mL of molybdate acid solution and 2 mL of ascorbic acid solution (40 g L⁻<sup>1</sup>) were previously added, and the volume was completed to approximately 50% with distilled water. Standards with 0; 0.2; 0.4; 0.6; 0.8; 1.0; 1.2; and 1.4 mg of P L<sup>1</sup>, were prepared. For each sample, 2.5 mL of the mineral solution was pipetted. After completing the flask volume and after approximately 5 min of reaction, 0.3 mL of the reading solution was transferred to ELISA microplates with 96 flat-bottomed wells. After the preparation of each plate, colorimetric readings were performed within 30 minutes.</p>
				<p>The above-described steps were performed for two consecutive days, in direct sequence, using the same operators and apparatuses. Thus, a total of ten batches, each consisting of one plate, were prepared. Per batch, standards were distributed across columns and rows, and samples were randomly distributed among the plates, in triplicate per plate (<xref ref-type="sec" rid="suppl">Supplementary material S1</xref>).</p>
			</sec>
			<sec>
				<title>2.4. Readings</title>
				<p>After preparation, the absorbance was measured, and images were obtained (<xref ref-type="fig" rid="f01">Figure 1</xref>).</p>
				<p>
					<fig id="f01">
						<label>Figure 1</label>
						<caption>
							<title>Representative scheme of the reading steps to get absorbance in a spectrophotometer and red, green and blue (RGB) data from images obtained by smartphone or scanner, for each microplate (pictures of microplates are real examples from this study of scanner and smartphone images).</title>
						</caption>
						<graphic xlink:href="1806-9290-rbz-55-e20250130-gf01.tif"/>
					</fig>
				</p>
				<sec>
					<title>2.4.1. Absorbance</title>
					<p>Absorbance at 725 nm (Multiskan Go, Thermo Scientific, Waltham, USA) was used as the standard method for quantifying P in the reading solutions.</p>
				</sec>
				<sec>
					<title>2.4.2. Images</title>
					<p><bold>2.4.2.1. Smartphone</bold></p>
					<p>To standardize the images and minimize the interference of external light, a cardboard dark box (<xref ref-type="bibr" rid="B4">Christodouleas et al., 2015</xref>) was made with a height of 42 cm, a depth of 35 cm, and a width of 39 cm. A 2 × 2 cm hole was made in the upper center to attach the smartphone camera. The light source used was a 24 W and 6500 K white LED luminaire measuring 30 × 30 cm and 3 cm in height (Avant, São Paulo, Brazil), centered at the bottom of the dark box. The plates were placed at the center of the light source, and images were obtained using a Galaxy A54 smartphone (Samsung Electronics, Seoul, South Korea) with automatic default image settings. Autofocus was used at the center of the plate to obtain each image. The distance between the camera lens and the top of the light source was 40 cm. The images were saved in JPEG format and with a resolution of 4032 × 3024 pixels.</p>
					<p><bold>2.4.2.2. Scanner</bold></p>
					<p>The plate was placed in the scanner such that the beam of light moved parallel to the longer side of the plate. A scanner CanoScan LiDE 300 (Canon Inc., Tokyo, Japan) was used. Corrections for brightness, contrast, etc., were not applied, and the standard settings of the equipment were adopted. The images were taken at 600 dpi and saved in JPEG format with dimensions of 3498 × 4962 pixels.</p>
				</sec>
			</sec>
		</sec>
		<sec>
			<title>2.5. Data extraction and processing</title>
			<p>All subsequent processing was performed using the ImageJ software (version 1.54f; <xref ref-type="bibr" rid="B20">Schneider et al., 2012</xref>). From the images obtained, all the plates were manually segmented into dimensions of 515 × 553 pixels. After segmentation, a circle of 10 pixels in diameter was selected in each microplate well, and the mean of the three RGB channels was obtained (<xref ref-type="fig" rid="f01">Figure 1</xref>).</p>
		</sec>
		<sec>
			<title>2.6. Calculations and statistical analysis</title>
			<sec>
				<title>2.6.1. Quantification of P in reading solutions</title>
				<p>For each plate, calibration curve parameters were estimated using PROC REG of SAS 9.4 (SAS Institute Inc., 2015), according to the following equation:</p>
				<disp-formula id="e1">
					<mml:math>
						<mml:mi>Y</mml:mi>
						<mml:mo>=</mml:mo>
						<mml:msub>
							<mml:mi>β</mml:mi>
							<mml:mn>0</mml:mn>
						</mml:msub>
						<mml:mo>+</mml:mo>
						<mml:msub>
							<mml:mi>β</mml:mi>
							<mml:mn>1</mml:mn>
						</mml:msub>
						<mml:mo>×</mml:mo>
						<mml:mi>P</mml:mi>
					</mml:math>
					<label>[1]</label>
				</disp-formula>
				<p>in which <italic>Y</italic> is the analytical signal, <italic>P</italic> is the concentration of phosphorus, <italic>β</italic><sub>0</sub> is the intercept, and <italic>β</italic><sub>1</sub> is the slope of the calibration curve.</p>
				<p>The P concentration in each reading solution was determined using the following equation:</p>
				<disp-formula id="e2">
					<mml:math>
						<mml:mo>[</mml:mo>
						<mml:mrow>
							<mml:mover>
								<mml:mi>P</mml:mi>
								<mml:mo>^</mml:mo>
							</mml:mover>
						</mml:mrow>
						<mml:msub>
							<mml:mo>]</mml:mo>
							<mml:mi>i</mml:mi>
						</mml:msub>
						<mml:mo>=</mml:mo>
						<mml:mfrac>
							<mml:mrow>
								<mml:msub>
									<mml:mi>L</mml:mi>
									<mml:mi>i</mml:mi>
								</mml:msub>
								<mml:mo>−</mml:mo>
								<mml:msub>
									<mml:mrow>
										<mml:mover>
											<mml:mi>β</mml:mi>
											<mml:mo>^</mml:mo>
										</mml:mover>
									</mml:mrow>
									<mml:mn>0</mml:mn>
								</mml:msub>
							</mml:mrow>
							<mml:msub>
								<mml:mrow>
									<mml:mover>
										<mml:mi>β</mml:mi>
										<mml:mo>^</mml:mo>
									</mml:mover>
								</mml:mrow>
								<mml:mn>1</mml:mn>
							</mml:msub>
						</mml:mfrac>
					</mml:math>
					<label>[2]</label>
				</disp-formula>
				<p>in which <inline-formula>
						<mml:math>
							<mml:mo>[</mml:mo>
							<mml:mrow>
								<mml:mover>
									<mml:mi>P</mml:mi>
									<mml:mo>^</mml:mo>
								</mml:mover>
							</mml:mrow>
							<mml:msub>
								<mml:mo>]</mml:mo>
								<mml:mi>i</mml:mi>
							</mml:msub>
						</mml:math>
					</inline-formula> is the P concentration for the reading solution of the <italic>i</italic>-th sample, <italic>L</italic><sub><italic>i</italic></sub> is the reading obtained for the <italic>i</italic>-th sample, and <inline-formula>
						<mml:math>
							<mml:msub>
								<mml:mrow>
									<mml:mover>
										<mml:mi>β</mml:mi>
										<mml:mo>^</mml:mo>
									</mml:mover>
								</mml:mrow>
								<mml:mn>0</mml:mn>
							</mml:msub>
						</mml:math>
					</inline-formula> and <inline-formula>
						<mml:math>
							<mml:msub>
								<mml:mrow>
									<mml:mover>
										<mml:mi>β</mml:mi>
										<mml:mo>^</mml:mo>
									</mml:mover>
								</mml:mrow>
								<mml:mn>1</mml:mn>
							</mml:msub>
						</mml:math>
					</inline-formula> are parameters estimated for using the standards described in Equation [1].</p>
			</sec>
			<sec>
				<title>2.6.2. Repeatability and detection limit</title>
				<p>For each predictor, a random model was used with the P concentration values obtained from the samples:</p>
				<disp-formula id="e3">
					<mml:math>
						<mml:mo>[</mml:mo>
						<mml:mi>P</mml:mi>
						<mml:msub>
							<mml:mo>]</mml:mo>
							<mml:mrow>
								<mml:mi>i</mml:mi>
								<mml:mi>j</mml:mi>
							</mml:mrow>
						</mml:msub>
						<mml:mo>=</mml:mo>
						<mml:mi>μ</mml:mi>
						<mml:mo>+</mml:mo>
						<mml:msub>
							<mml:mi>A</mml:mi>
							<mml:mi>i</mml:mi>
						</mml:msub>
						<mml:mo>+</mml:mo>
						<mml:msub>
							<mml:mi>ε</mml:mi>
							<mml:mrow>
								<mml:mi>i</mml:mi>
								<mml:mi>j</mml:mi>
							</mml:mrow>
						</mml:msub>
					</mml:math>
					<label>[3]</label>
				</disp-formula>
				<p>in which [<italic>P</italic>]<sub><italic>ij</italic></sub> is the P content in replicate <italic>j</italic> of sample <italic>i</italic>, <italic>μ</italic> is the general constant, <italic>A</italic><sub><italic>i</italic></sub> is the random effect of the <italic>i</italic>-th sample, and <italic>ε</italic><sub><italic>ij</italic></sub> is the random error between replicates. Sample <inline-formula>
						<mml:math>
							<mml:mrow>
								<mml:mo>(</mml:mo>
								<mml:msubsup>
									<mml:mrow>
										<mml:mover>
											<mml:mi>σ</mml:mi>
											<mml:mo>^</mml:mo>
										</mml:mover>
									</mml:mrow>
									<mml:mi>s</mml:mi>
									<mml:mn>2</mml:mn>
								</mml:msubsup>
								<mml:mo>)</mml:mo>
							</mml:mrow>
						</mml:math>
					</inline-formula> and residual <inline-formula>
						<mml:math>
							<mml:mrow>
								<mml:mo>(</mml:mo>
								<mml:msubsup>
									<mml:mrow>
										<mml:mover>
											<mml:mi>σ</mml:mi>
											<mml:mo>^</mml:mo>
										</mml:mover>
									</mml:mrow>
									<mml:mi>r</mml:mi>
									<mml:mn>2</mml:mn>
								</mml:msubsup>
								<mml:mo>)</mml:mo>
							</mml:mrow>
						</mml:math>
					</inline-formula> variances were estimated by restricted maximum likelihood.</p>
				<p>The standardized repeatability as a function of the average P was calculated as follows:</p>
				<disp-formula id="e4">
					<mml:math>
						<mml:mtext> Repeatability </mml:mtext>
						<mml:mo>(</mml:mo>
						<mml:mi>%</mml:mi>
						<mml:mo>)</mml:mo>
						<mml:mo>=</mml:mo>
						<mml:mn>100</mml:mn>
						<mml:mo>×</mml:mo>
						<mml:mfrac>
							<mml:msubsup>
								<mml:mrow>
									<mml:mover>
										<mml:mi>σ</mml:mi>
										<mml:mo>^</mml:mo>
									</mml:mover>
								</mml:mrow>
								<mml:mi>r</mml:mi>
								<mml:mn>2</mml:mn>
							</mml:msubsup>
							<mml:mrow>
								<mml:mover>
									<mml:mi>P</mml:mi>
									<mml:mo>¯</mml:mo>
								</mml:mover>
							</mml:mrow>
						</mml:mfrac>
					</mml:math>
					<label>[4]</label>
				</disp-formula>
				<p>in which δ<sup>2</sup><sub>r</sub> is the residual variance obtained in Equation [3], and <italic>P</italic>̅ is the mean P concentration in the reading solution for each sample and quantification method.</p>
				<p>The limit of detection (LOD) was calculated using the following equation:</p>
				<disp-formula id="e5">
					<mml:math>
						<mml:mi>L</mml:mi>
						<mml:mi>O</mml:mi>
						<mml:mi>D</mml:mi>
						<mml:mo>=</mml:mo>
						<mml:mn>3.3</mml:mn>
						<mml:mo>×</mml:mo>
						<mml:mfrac>
							<mml:msub>
								<mml:mi>S</mml:mi>
								<mml:mrow>
									<mml:mi>P</mml:mi>
									<mml:mn>0</mml:mn>
								</mml:mrow>
							</mml:msub>
							<mml:msub>
								<mml:mrow>
									<mml:mover>
										<mml:mi>β</mml:mi>
										<mml:mo>^</mml:mo>
									</mml:mover>
								</mml:mrow>
								<mml:mn>1</mml:mn>
							</mml:msub>
						</mml:mfrac>
					</mml:math>
					<label>[5]</label>
				</disp-formula>
				<p>in which <italic>s</italic><sub><italic>P</italic>0</sub> is the standard deviation in the white aliquots and <inline-formula>
						<mml:math>
							<mml:msub>
								<mml:mrow>
									<mml:mover>
										<mml:mi>β</mml:mi>
										<mml:mo>^</mml:mo>
									</mml:mover>
								</mml:mrow>
								<mml:mn>1</mml:mn>
							</mml:msub>
						</mml:math>
					</inline-formula> is the regressor of the calibration curve, obtained using Equation [1].</p>
				<p>The limit of quantification (LOQ) was calculated as:</p>
				<disp-formula id="e6">
					<mml:math>
						<mml:mi>L</mml:mi>
						<mml:mi>O</mml:mi>
						<mml:mi>Q</mml:mi>
						<mml:mo>=</mml:mo>
						<mml:mn>10</mml:mn>
						<mml:mo>×</mml:mo>
						<mml:mfrac>
							<mml:msub>
								<mml:mi>S</mml:mi>
								<mml:mrow>
									<mml:mi>P</mml:mi>
									<mml:mn>0</mml:mn>
								</mml:mrow>
							</mml:msub>
							<mml:msub>
								<mml:mrow>
									<mml:mover>
										<mml:mi>β</mml:mi>
										<mml:mo>^</mml:mo>
									</mml:mover>
								</mml:mrow>
								<mml:mn>1</mml:mn>
							</mml:msub>
						</mml:mfrac>
					</mml:math>
					<label>[6]</label>
				</disp-formula>
				<p>in which <italic>s</italic><sub><italic>P</italic>0</sub> is the standard deviation in the white aliquots and <inline-formula>
						<mml:math>
							<mml:msub>
								<mml:mrow>
									<mml:mover>
										<mml:mi>β</mml:mi>
										<mml:mo>^</mml:mo>
									</mml:mover>
								</mml:mrow>
								<mml:mn>1</mml:mn>
							</mml:msub>
						</mml:math>
					</inline-formula> is the regressor of the calibration curve, obtained in Equation [1].</p>
			</sec>
			<sec>
				<title>2.6.3. Comparison of methods</title>
				<p>To compare the average P determined in reading solutions by the image acquisition method, repeated measures ANOVA was performed using the PROC GLIMMIX procedure in SAS 9.4 (SAS Institute Inc., 2015). The statistical model was:</p>
				<disp-formula id="e7">
					<mml:math>
						<mml:mo>[</mml:mo>
						<mml:mi>P</mml:mi>
						<mml:msub>
							<mml:mo>]</mml:mo>
							<mml:mrow>
								<mml:mi>i</mml:mi>
								<mml:mi>j</mml:mi>
								<mml:mi>k</mml:mi>
								<mml:mi>l</mml:mi>
							</mml:mrow>
						</mml:msub>
						<mml:mo>=</mml:mo>
						<mml:mi>μ</mml:mi>
						<mml:mo>+</mml:mo>
						<mml:msub>
							<mml:mi>M</mml:mi>
							<mml:mi>i</mml:mi>
						</mml:msub>
						<mml:mo>+</mml:mo>
						<mml:msub>
							<mml:mi>β</mml:mi>
							<mml:mi>j</mml:mi>
						</mml:msub>
						<mml:mo>+</mml:mo>
						<mml:msub>
							<mml:mi>δ</mml:mi>
							<mml:mrow>
								<mml:mi>i</mml:mi>
								<mml:mi>j</mml:mi>
							</mml:mrow>
						</mml:msub>
						<mml:mo>+</mml:mo>
						<mml:msub>
							<mml:mi>γ</mml:mi>
							<mml:mi>k</mml:mi>
						</mml:msub>
						<mml:mo>+</mml:mo>
						<mml:msub>
							<mml:mi>ε</mml:mi>
							<mml:mrow>
								<mml:mi>i</mml:mi>
								<mml:mi>j</mml:mi>
								<mml:mi>k</mml:mi>
								<mml:mi>l</mml:mi>
							</mml:mrow>
						</mml:msub>
					</mml:math>
					<label>[7]</label>
				</disp-formula>
				<p>in which [<italic>P</italic>]<sub><italic>ijkl</italic></sub> is the P concentration in the reading solution, <italic>μ</italic> is the overall mean, <italic>M</italic><sub><italic>i</italic></sub> is the fixed effect of the method (repeated measure), <italic>β</italic><sub><italic>j</italic></sub> is the random intercept associated with plate (subject), <italic>δ</italic><sub><italic>ij</italic></sub> is the random effect of image within plate (subject) assuming unstructured covariance matrix (UN), <italic>γ</italic><sub><italic>k</italic></sub> is the random effect of the sample, and <italic>ε</italic><sub><italic>ijkl</italic></sub> is the residual error.</p>
				<p>The model was fitted using the P concentration in the reading solution, determined by the mean values of each channel. As absorbance was assumed to be the gold standard, the least-squares mean of the scanner and smartphone images was compared using a paired t-test relative to absorbance. To minimize type II error, differences were tested considering alpha equal to 0.10.</p>
				<p>Based on the higher slope in Equation 1 (sensitivity) and lower REP, LOD, and LOQ values, the best-performing image type and channel was selected. A linear regression between the average P concentration in each sample using the absorbance results and the best-performing alternative method was estimated. The null hypothesis of intercept equal to zero and slope equal to one were tested considering alpha equal to 0.01.</p>
			</sec>
		</sec>
		<sec sec-type="results">
			<title>3. Results</title>
			<p>An inverse relationship between color values and P concentration was observed for all channels and devices, whereas the absorbance was positively correlated with P (<xref ref-type="fig" rid="f02">Figure 2</xref>).</p>
			<p>
				<fig id="f02">
					<label>Figure 2</label>
					<caption>
						<title>Scatterplots with mean intercept (<italic>β</italic>0) and slope (<italic>β</italic>1) of each RGB predictor or absorbance as a function of standard solutions from 0 to 1.4 mg L−1 of P in images obtained by smartphone or scanner (each line refers to plates).</title>
					</caption>
					<graphic xlink:href="1806-9290-rbz-55-e20250130-gf02.tif"/>
				</fig>
			</p>
			<p>Lower repeatability values, LOD, and LOQ of 0.96%, 0.013, and 0.039 mg L<sup>1</sup>, respectively, were observed using absorbance as a predictor (<xref ref-type="table" rid="t1">Table 1</xref>). Lower repeatability values, LOD, and LOQ were observed for smartphone images, with minimum repeatability values using red as a predictor of 1.80%, 0.050, and 0.150 mg L⁻<sup>1</sup>, respectively. From all evaluated channels and devices, only the blue channel using scanner images provided a P concentration different from that obtained by the absorbance method (P&lt;0.10).</p>
			<p>
				<table-wrap id="t1">
					<label>Table 1</label>
					<caption>
						<title>Phosphorus concentration <inline-formula>
								<mml:math>
									<mml:mo>(</mml:mo>
									<mml:mrow>
										<mml:mover>
											<mml:mi>P</mml:mi>
											<mml:mo>^</mml:mo>
										</mml:mover>
									</mml:mrow>
									<mml:mo>)</mml:mo>
								</mml:math>
							</inline-formula> in reading solutions of feed samples (n = 24), variance within samples <inline-formula>
								<mml:math>
									<mml:mrow>
										<mml:mo>(</mml:mo>
										<mml:msubsup>
											<mml:mrow>
												<mml:mover>
													<mml:mi>σ</mml:mi>
													<mml:mo>^</mml:mo>
												</mml:mover>
											</mml:mrow>
											<mml:mi>s</mml:mi>
											<mml:mn>2</mml:mn>
										</mml:msubsup>
										<mml:mo>)</mml:mo>
									</mml:mrow>
								</mml:math>
							</inline-formula>, residual variance <inline-formula>
								<mml:math>
									<mml:mrow>
										<mml:mo>(</mml:mo>
										<mml:msubsup>
											<mml:mrow>
												<mml:mover>
													<mml:mi>σ</mml:mi>
													<mml:mo>^</mml:mo>
												</mml:mover>
											</mml:mrow>
											<mml:mi>r</mml:mi>
											<mml:mn>2</mml:mn>
										</mml:msubsup>
										<mml:mo>)</mml:mo>
									</mml:mrow>
								</mml:math>
							</inline-formula>, repeatability (REP), limit of detection (LOD) and limit of quantification (LOQ) determined using absorbance or mean RGB values in images obtained by smartphone or scanner</title>
					</caption>
					<table frame="hsides" rules="groups">
						<colgroup>
							<col/>
							<col/>
							<col/>
							<col/>
							<col/>
							<col/>
							<col/>
							<col/>
							<col/>
							<col/>
						</colgroup>
						<thead>
							<tr>
								<th align="left" rowspan="3" style="font-weight:normal">Item</th>
								<th rowspan="2" style="font-weight:normal">Spectrophotometer</th>
								<th align="left" rowspan="3" style="font-weight:normal"> </th>
								<th colspan="7" style="font-weight:normal">Device/channel</th>
							</tr>
							<tr>
								<th colspan="3" style="font-weight:normal">Smartphone</th>
								<th align="left" rowspan="2" style="font-weight:normal"> </th>
								<th colspan="3" style="font-weight:normal">Scanner</th>
							</tr>
							<tr>
								<th style="font-weight:normal">Absorbance</th>
								<th style="font-weight:normal">Red</th>
								<th style="font-weight:normal">Green</th>
								<th style="font-weight:normal">Blue</th>
								<th style="font-weight:normal">Red</th>
								<th style="font-weight:normal">Green</th>
								<th style="font-weight:normal">Blue</th>
							</tr>
						</thead>
						<tbody>
							<tr>
								<td>ˆ<italic>P</italic> (mg L<sup>−1</sup>)<sup>1</sup></td>
								<td align="center">0.43±0.013</td>
								<td> </td>
								<td align="center">0.44±0.013</td>
								<td align="center">0.44±0.013</td>
								<td align="center">0.42±0.014</td>
								<td> </td>
								<td align="center">0.42±0.014</td>
								<td align="center">0.40±0.015</td>
								<td align="center">0.37±0.016</td>
							</tr>
							<tr>
								<td>P-value<sup>2</sup></td>
								<td align="center">-</td>
								<td> </td>
								<td align="center">0.947</td>
								<td align="center">0.991</td>
								<td align="center">0.917</td>
								<td> </td>
								<td align="center">0.889</td>
								<td align="center">0.329</td>
								<td align="center">0.035</td>
							</tr>
							<tr>
								<td>
									<inline-formula>
										<mml:math>
											<mml:msubsup>
												<mml:mrow>
													<mml:mover>
														<mml:mi>σ</mml:mi>
														<mml:mo>^</mml:mo>
													</mml:mover>
												</mml:mrow>
												<mml:mi>s</mml:mi>
												<mml:mn>2</mml:mn>
											</mml:msubsup>
										</mml:math>
									</inline-formula>
								</td>
								<td align="center">0.1194</td>
								<td> </td>
								<td align="center">0.1209</td>
								<td align="center">0.1131</td>
								<td align="center">0.1094</td>
								<td> </td>
								<td align="center">0.1236</td>
								<td align="center">0.1150</td>
								<td align="center">0.1056</td>
							</tr>
							<tr>
								<td>
									<inline-formula>
										<mml:math>
											<mml:msubsup>
												<mml:mrow>
													<mml:mover>
														<mml:mi>σ</mml:mi>
														<mml:mo>^</mml:mo>
													</mml:mover>
												</mml:mrow>
												<mml:mi>r</mml:mi>
												<mml:mn>2</mml:mn>
											</mml:msubsup>
										</mml:math>
									</inline-formula>
								</td>
								<td align="center">0.0041</td>
								<td> </td>
								<td align="center">0.0079</td>
								<td align="center">0.0092</td>
								<td align="center">0.0349</td>
								<td> </td>
								<td align="center">0.0153</td>
								<td align="center">0.0379</td>
								<td align="center">0.0763</td>
							</tr>
							<tr>
								<td>REP (%)</td>
								<td align="center">0.96</td>
								<td> </td>
								<td align="center">1.80</td>
								<td align="center">2.11</td>
								<td align="center">8.39</td>
								<td> </td>
								<td align="center">3.68</td>
								<td align="center">9.58</td>
								<td align="center">20.45</td>
							</tr>
							<tr>
								<td>LOD (mg L<sup>−1</sup>)</td>
								<td align="center">0.013</td>
								<td> </td>
								<td align="center">0.050</td>
								<td align="center">0.074</td>
								<td align="center">0.333</td>
								<td> </td>
								<td align="center">0.426</td>
								<td align="center">0.667</td>
								<td align="center">0.936</td>
							</tr>
							<tr>
								<td>LOQ (mg L<sup>−1</sup>)</td>
								<td align="center">0.039</td>
								<td> </td>
								<td align="center">0.150</td>
								<td align="center">0.223</td>
								<td align="center">1.010</td>
								<td> </td>
								<td align="center">1.289</td>
								<td align="center">2.022</td>
								<td align="center">2.835</td>
							</tr>
						</tbody>
					</table>
					<table-wrap-foot>
						<fn id="TFN1">
							<p><sup>1</sup> Least-squares means.</p>
						</fn>
						<fn id="TFN2">
							<p><sup>2</sup> Paired t-test of <inline-formula>
									<mml:math>
										<mml:mrow>
											<mml:mover>
												<mml:mi>P</mml:mi>
												<mml:mo>^</mml:mo>
											</mml:mover>
										</mml:mrow>
									</mml:math>
								</inline-formula> relative to absorbance, from repeated measures ANOVA analysis.</p>
						</fn>
					</table-wrap-foot>
				</table-wrap>
			</p>
			<p>As the red channel in smartphone images had a higher slope in Equation [1] (<xref ref-type="fig" rid="f02">Figure 2</xref>) and the lowest REP, LOD, and LOQ (<xref ref-type="table" rid="t1">Table 1</xref>), the P concentration for each sample was regressed against P determined by absorbance (<xref ref-type="fig" rid="f03">Figure 3</xref>). The intercept and slope did not differ from zero (P = 0.128) and one (P = 0.369), respectively.</p>
			<p>
				<fig id="f03">
					<label>Figure 3</label>
					<caption>
						<title>Phosphorus (P) concentration (as received) determined by absorbance at 725 nm in spectrophotometer as a linear function of P determined by mean red channel in smartphone images (<italic>β</italic>0 and <italic>β</italic>1 are intercept and slope, respectively; n = 24).</title>
					</caption>
					<graphic xlink:href="1806-9290-rbz-55-e20250130-gf03.tif"/>
				</fig>
			</p>
		</sec>
		<sec sec-type="discussion">
			<title>4. Discussion</title>
			<p>Except for the blue channel of the scanner images, all evaluated colorimetric methods provided mean P concentration values that were not different from those obtained by absorbance. The differences between the remaining methods and absorbance mainly relied on repeatability, LOD, and LOQ, which were lower for red, followed by green in the smartphone images. Additionally, the higher slope for the red channel in the smartphone indicates higher sensitivity and highlights it as the best channel and image type. Considering the comparison of P determination by the red channel in smartphone images and absorbance, the desired intercept not different from zero and slope not different from one were observed (Cantwell, 2025). Together, these results suggest a potential similarity between absorbance and the red channel of smartphone-based imaging, which may be useful for developing alternative analytical methods. However, this was an intra-laboratory analysis and should be interpreted as a proof-of-concept study with limited scope.</p>
			<p>It is important to mention the upper limit of intra-laboratory repeatability of 12%, calculated by the Horwitz equation using the average 0.429 mg L<sup>1</sup> of P (<xref ref-type="bibr" rid="B13">Horwitz and Albert, 2006</xref>). Considering other studies using the molybdenum blue method for P analysis in feeds or foods, a safe threshold of 2.5% can be considered for this study (<xref ref-type="bibr" rid="B18">Pulliainen and Wallin, 1996</xref>; <xref ref-type="bibr" rid="B14">McKie and McCleary, 2016</xref>; Gliszczyńska-Świgło and Rybicka, 2021). The repeatability value of 0.96% observed for absorbance was close to the lower value of 1.1% reported in the reference study of <xref ref-type="bibr" rid="B18">Pulliainen and Wallin (1996)</xref>. This indicates that random factors were properly controlled in the spectrophotometer analysis of the present study, and that it is suitable to be interpreted as the gold standard. Satisfactory repeatability was observed for the red and green channels of the smartphone images, with values of 1.80 and 2.11%, respectively. These repeatability values are promising and support future collaborative studies to evaluate reproducibility.</p>
			<p>The red channel of smartphone images had LOD and LOQ of 0.050 and 0.150 mg L<sup>1</sup>, respectively, which are lower than 0.37 and 1.13 reported by Gliszczyńska-Świgło and Rybicka (2021), who used absorbance in a microplate spectrophotometer to analyze P in dairy products. Although using conventional glass cuvettes and other specificities the apparatus (i.e., dark box and light source), LOD and LOQ of 1.60 and 2.30 mg L<sup>1</sup> with repeatability of 2% were reported using smartphone images to measure P in water, soil, and biofertilizers (<xref ref-type="bibr" rid="B7">de Souza et al., 2023</xref>). This demonstrates that the results are within acceptable standards of LOD and LOQ for image-based methods proposed for P analysis in other types of sample matrices.</p>
			<p>Studies evaluating and using image analysis and colorimetric methods have utilized scanners as the main device, mainly based on the ReadPlate plug-in for ImageJ (<xref ref-type="bibr" rid="B1">Angelani et al., 2018</xref>; <xref ref-type="bibr" rid="B10">Filgueiras et al., 2022</xref>). Owing to the scanner’s intrinsic standardization of the light source, image resolution, and lower external light interference during image acquisition, better or similar performance compared with smartphones was expected. However, smartphone images provided lower repeatability, LOD, and LOQ than scanner images. The use of smartphones may be preferable to scanners because it opens the possibility of analysis using portable and popular devices that are widely available. Although more susceptible to factors such as ambient light, sample position, and focus distance, which affect the accuracy of image-based colorimetric analysis (<xref ref-type="bibr" rid="B23">Vargas-Muñoz et al., 2023</xref>), these were minimally standardized in this study using a low-cost dark box and light source. Solutions, such as the microplate reader proposed by <xref ref-type="bibr" rid="B2">Bergua et al. (2022)</xref>, can be used as an example of the development of a specific and simple apparatus for colorimetric analysis using smartphones. Although differences among smartphone models are not expected, studies comparing inter-device reliability and reproducibility are still needed. Several potential improvements to the apparatus, mainly in defining optimal distances for imaging, as well as the color temperature and power of the light source coupled to the ELISA plate, can be made.</p>
			<p>In addition to aspects related to imaging devices and apparatus, key chemical aspects related to analytical procedures may interact with image data and can be optimized in future studies. When the molybdenum blue method was proposed by <xref ref-type="bibr" rid="B11">Fiske and Subbarow (1925)</xref>, the authors highlighted various substances and analytical approaches that may affect color development. Different digestion methods, variations in reducing agents and catalysts, proportions of mineral solutions, and integration with pre-concentration and separation processes are relevant issues to be evaluated and can interact with colorimetric analysis (<xref ref-type="bibr" rid="B9">Divrikli et al., 2009</xref>; <xref ref-type="bibr" rid="B15">Mogashane et al., 2025</xref>). For instance, the concentrations of sulfuric acid, ammonium molybdate, ascorbic acid, and potassium antimonyl tartrate solutions affected the RGB values of a polymer developed for phosphate analysis in water (<xref ref-type="bibr" rid="B24">Wongniramaikul and Choodum, 2017</xref>). Another example of variations in the method is the study by <xref ref-type="bibr" rid="B16">Moonrungsee et al. (2015)</xref>, who proposed an image-based colorimetric method for P in soil solutions using potassium antimonyl tartrate as a catalyst, which was omitted in our study. Thus, advances in analytical procedures for image colorimetry in P analysis in animal feeds depend on factorial studies evaluating these interactions from sample preparation to colorimetric analysis.</p>
		</sec>
		<sec sec-type="conclusions">
			<title>5. Conclusions</title>
			<p>The concept of using RGB data from digital images captured using low-cost and easily accessible devices and microplates proved to be feasible for determining P concentration in animal feeds using the molybdenum blue colorimetric method. Images from the smartphone showed greater potential than those from the scanner, and when using data from the red channel, they showed significant predictive potential, with low repeatability and detection and quantification limits. The results open perspectives for future studies aimed at enhancing the technology readiness level, considering that smartphones are accessible and popular instruments.</p>
		</sec>
		<sec id="suppl" sec-type="supplementary-material">
			<title>Supplementary material</title>
			<supplementary-material id="suppl01">
				<label>Supplementary material S1</label>
				<media mime-subtype="xlsx" mimetype="application" xlink:href="1806-9290-rbz-55-e20250130-suppl01.xlsx"/>
			</supplementary-material>
		</sec>
	</body>
	<back>
		<ref-list>
			<title>References</title>
			<ref id="B1">
				<mixed-citation>Angelani, C. R.; Carabias, P.; Cruz, K. M.; Delfino, J. M.; Sautu, M.; Espelt, M. V.; Ferreira-Gomes, M. S.; Gómez, G. E.; Mangialavori, I. C.; Manzi, M.; Pignataro, M. F.; Saffioti, N. A.; Salvatierra Fréchou, D. M.; Santos, J. and Schwarzbaum, P. J. 2018. A metabolic control analysis approach to introduce the study of systems in biochemistry: the glycolytic pathway in the red blood cell. Biochemistry and Molecular Biology Education 46:502-515. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/bmb.21139">https://doi.org/10.1002/bmb.21139</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Angelani</surname>
							<given-names>C. R.</given-names>
						</name>
						<name>
							<surname>Carabias</surname>
							<given-names>P.</given-names>
						</name>
						<name>
							<surname>Cruz</surname>
							<given-names>K. M.</given-names>
						</name>
						<name>
							<surname>Delfino</surname>
							<given-names>J. M.</given-names>
						</name>
						<name>
							<surname>Sautu</surname>
							<given-names>M.</given-names>
						</name>
						<name>
							<surname>Espelt</surname>
							<given-names>M. V.</given-names>
						</name>
						<name>
							<surname>Ferreira-Gomes</surname>
							<given-names>M. S.</given-names>
						</name>
						<name>
							<surname>Gómez</surname>
							<given-names>G. E.</given-names>
						</name>
						<name>
							<surname>Mangialavori</surname>
							<given-names>I. C.</given-names>
						</name>
						<name>
							<surname>Manzi</surname>
							<given-names>M.</given-names>
						</name>
						<name>
							<surname>Pignataro</surname>
							<given-names>M. F.</given-names>
						</name>
						<name>
							<surname>Saffioti</surname>
							<given-names>N. A.</given-names>
						</name>
						<name>
							<surname>Salvatierra Fréchou</surname>
							<given-names>D. M.</given-names>
						</name>
						<name>
							<surname>Santos</surname>
							<given-names>J.</given-names>
						</name>
						<name>
							<surname>Schwarzbaum</surname>
							<given-names>P. J.</given-names>
						</name>
					</person-group>
					<year>2018</year>
					<article-title>A metabolic control analysis approach to introduce the study of systems in biochemistry: the glycolytic pathway in the red blood cell</article-title>
					<source>Biochemistry and Molecular Biology Education</source>
					<volume>46</volume>
					<fpage>502</fpage>
					<lpage>515</lpage>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/bmb.21139">https://doi.org/10.1002/bmb.21139</ext-link>
					</comment>
				</element-citation>
			</ref>
			<ref id="B2">
				<mixed-citation>Bergua, J. F.; Álvarez-Diduk, R.; Idili, A.; Parolo, C.; Maymó, M.; Hu, L. and Merkoçi, A. 2022. Low-cost, user-friendly, all-integrated smartphone-based microplate reader for optical-based biological and chemical analyses. Analytical Chemistry 94:1271-1285. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1021/acs.analchem.1c04491">https://doi.org/10.1021/acs.analchem.1c04491</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Bergua</surname>
							<given-names>J. F.</given-names>
						</name>
						<name>
							<surname>Álvarez-Diduk</surname>
							<given-names>R.</given-names>
						</name>
						<name>
							<surname>Idili</surname>
							<given-names>A.</given-names>
						</name>
						<name>
							<surname>Parolo</surname>
							<given-names>C.</given-names>
						</name>
						<name>
							<surname>Maymó</surname>
							<given-names>M.</given-names>
						</name>
						<name>
							<surname>Hu</surname>
							<given-names>L.</given-names>
						</name>
						<name>
							<surname>Merkoçi</surname>
							<given-names>A.</given-names>
						</name>
					</person-group>
					<year>2022</year>
					<article-title>Low-cost, user-friendly, all-integrated smartphone-based microplate reader for optical-based biological and chemical analyses</article-title>
					<source>Analytical Chemistry</source>
					<volume>94</volume>
					<fpage>1271</fpage>
					<lpage>1285</lpage>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1021/acs.analchem.1c04491">https://doi.org/10.1021/acs.analchem.1c04491</ext-link>
					</comment>
				</element-citation>
			</ref>
			<ref id="B3">
				<mixed-citation>Cantwell, H. 2025. Eurachem guide: The fitness for purpose of analytical methods – A laboratory guide to method validation and related topics. 3rd ed. Available at: &lt;<ext-link ext-link-type="uri" xlink:href="http://www.eurachem.org&gt;">http://www.eurachem.org</ext-link>&gt;. Accessed on: June 02,2025.</mixed-citation>
				<element-citation publication-type="webpage">
					<person-group person-group-type="author">
						<name>
							<surname>Cantwell</surname>
							<given-names>H.</given-names>
						</name>
					</person-group>
					<year>2025</year>
					<source>Eurachem guide: The fitness for purpose of analytical methods – A laboratory guide to method validation and related topics</source>
					<edition>3rd</edition>
					<ext-link ext-link-type="uri" xlink:href="http://www.eurachem.org">http://www.eurachem.org</ext-link>
					<date-in-citation content-type="access-date">Accessed on: June 02,2025</date-in-citation>
				</element-citation>
			</ref>
			<ref id="B4">
				<mixed-citation>Christodouleas, D. C.; Nemiroski, A.; Kumar, A. A. and Whitesides, G. M. 2015. Broadly available imaging devices enable high-quality low-cost photometry. Analytical Chemistry 87:9170-9178. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1021/acs.analchem.5b01612">https://doi.org/10.1021/acs.analchem.5b01612</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Christodouleas</surname>
							<given-names>D. C.</given-names>
						</name>
						<name>
							<surname>Nemiroski</surname>
							<given-names>A.</given-names>
						</name>
						<name>
							<surname>Kumar</surname>
							<given-names>A. A.</given-names>
						</name>
						<name>
							<surname>Whitesides</surname>
							<given-names>G. M.</given-names>
						</name>
					</person-group>
					<year>2015</year>
					<article-title>Broadly available imaging devices enable high-quality low-cost photometry</article-title>
					<source>Analytical Chemistry</source>
					<volume>87</volume>
					<fpage>9170</fpage>
					<lpage>9178</lpage>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1021/acs.analchem.5b01612">https://doi.org/10.1021/acs.analchem.5b01612</ext-link>
					</comment>
				</element-citation>
			</ref>
			<ref id="B5">
				<mixed-citation>Colzani, H.; Rodrigues, Q. E. A. G.; Fogaça, C.; Gelinski, J. M. L. N.; Pereira-Filho, E. R. and Borges, E. M. 2017. Determinação de fosfato em refrigerantes utilizando um scanner de mesa e análise automatizada de dados: um exemplo didático para ensino de química. Química Nova 40:833-839. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.21577/0100-4042.20170035">https://doi.org/10.21577/0100-4042.20170035</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Colzani</surname>
							<given-names>H.</given-names>
						</name>
						<name>
							<surname>Rodrigues</surname>
							<given-names>Q. E. A. G.</given-names>
						</name>
						<name>
							<surname>Fogaça</surname>
							<given-names>C.</given-names>
						</name>
						<name>
							<surname>Gelinski</surname>
							<given-names>J. M. L. N.</given-names>
						</name>
						<name>
							<surname>Pereira-Filho</surname>
							<given-names>E. R.</given-names>
						</name>
						<name>
							<surname>Borges</surname>
							<given-names>E. M.</given-names>
						</name>
					</person-group>
					<year>2017</year>
					<article-title>Determinação de fosfato em refrigerantes utilizando um scanner de mesa e análise automatizada de dados: um exemplo didático para ensino de química</article-title>
					<source>Química Nova</source>
					<volume>40</volume>
					<fpage>833</fpage>
					<lpage>839</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.21577/0100-4042.20170035">https://doi.org/10.21577/0100-4042.20170035</ext-link>
				</element-citation>
			</ref>
			<ref id="B6">
				<mixed-citation>Curbani, L.; Gelinski, J. M. L. N. and Borges, E. M. 2020. Determination of ethanol in beers using a flatbed scanner and automated digital image analysis. Food Analytical Methods 13:249-259. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/S12161-019-01611-7">https://doi.org/10.1007/S12161-019-01611-7</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Curbani</surname>
							<given-names>L.</given-names>
						</name>
						<name>
							<surname>Gelinski</surname>
							<given-names>J. M. L. N.</given-names>
						</name>
						<name>
							<surname>Borges</surname>
							<given-names>E. M.</given-names>
						</name>
					</person-group>
					<year>2020</year>
					<article-title>Determination of ethanol in beers using a flatbed scanner and automated digital image analysis</article-title>
					<source>Food Analytical Methods</source>
					<volume>13</volume>
					<fpage>249</fpage>
					<lpage>259</lpage>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/S12161-019-01611-7">https://doi.org/10.1007/S12161-019-01611-7</ext-link>
					</comment>
				</element-citation>
			</ref>
			<ref id="B7">
				<mixed-citation>de Souza, V. S.; Silva, S. M. S.; Maia, L. C.; Monteiro, D. S. and Souza, A. L. V. 2023. Development of a methodology for phosphorus determination in soils, water, and biofertilizer using digital image analysis - DIA. Chemometrics and Intelligent Laboratory Systems 240:104929. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.chemolab.2023.104929">https://doi.org/10.1016/j.chemolab.2023.104929</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>de Souza</surname>
							<given-names>V. S.</given-names>
						</name>
						<name>
							<surname>Silva</surname>
							<given-names>S. M. S.</given-names>
						</name>
						<name>
							<surname>Maia</surname>
							<given-names>L. C.</given-names>
						</name>
						<name>
							<surname>Monteiro</surname>
							<given-names>D. S.</given-names>
						</name>
						<name>
							<surname>Souza</surname>
							<given-names>A. L. V.</given-names>
						</name>
					</person-group>
					<year>2023</year>
					<article-title>Development of a methodology for phosphorus determination in soils, water, and biofertilizer using digital image analysis - DIA</article-title>
					<source>Chemometrics and Intelligent Laboratory Systems</source>
					<volume>240</volume>
					<size units="pages">104929</size>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.chemolab.2023.104929">https://doi.org/10.1016/j.chemolab.2023.104929</ext-link>
				</element-citation>
			</ref>
			<ref id="B8">
				<mixed-citation>Detmann, E.; Rodrigues, J. P. P.; Silva, T. E.; Brito Neto, A. S. and Franco, M. O. 2025. Methods for feed analysis. 3rd ed. INCT - Animal Science. Suprema, Visconde do Rio Branco.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>Detmann</surname>
							<given-names>E.</given-names>
						</name>
						<name>
							<surname>Rodrigues</surname>
							<given-names>J. P. P.</given-names>
						</name>
						<name>
							<surname>Silva</surname>
							<given-names>T. E.</given-names>
						</name>
						<name>
							<surname>Brito</surname>
							<given-names>A. S.</given-names>
							<suffix>Neto</suffix>
						</name>
						<name>
							<surname>Franco</surname>
							<given-names>M. O.</given-names>
						</name>
					</person-group>
					<year>2025</year>
					<source>Methods for feed analysis</source>
					<edition>3rd</edition>
					<publisher-name>INCT - Animal Science</publisher-name>
					<publisher-loc>Suprema</publisher-loc>
					<publisher-name>Visconde do Rio Branco</publisher-name>
				</element-citation>
			</ref>
			<ref id="B9">
				<mixed-citation>Divrikli, U.; Akdogan, A.; Soylak, M. and Elci, L. 2009. Factorial design for multivariate optimization of preconcentration system for spectrophotometric phosphorus determination. Talanta 79:1287-1291. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.talanta.2009.05.046">https://doi.org/10.1016/j.talanta.2009.05.046</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Divrikli</surname>
							<given-names>U.</given-names>
						</name>
						<name>
							<surname>Akdogan</surname>
							<given-names>A.</given-names>
						</name>
						<name>
							<surname>Soylak</surname>
							<given-names>M.</given-names>
						</name>
						<name>
							<surname>Elci</surname>
							<given-names>L.</given-names>
						</name>
					</person-group>
					<year>2009</year>
					<article-title>Factorial design for multivariate optimization of preconcentration system for spectrophotometric phosphorus determination</article-title>
					<source>Talanta</source>
					<volume>79</volume>
					<fpage>1287</fpage>
					<lpage>1291</lpage>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.talanta.2009.05.046">https://doi.org/10.1016/j.talanta.2009.05.046</ext-link>
					</comment>
				</element-citation>
			</ref>
			<ref id="B10">
				<mixed-citation>Filgueiras, M. F.; Lima, B. O. and Borges, E. M. 2022. A high-throughput, cheap, and green method for determination of ethanol in cachaça and vodka using 96-well-plate images. Talanta 241:123229. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.talanta.2022.123229">https://doi.org/10.1016/j.talanta.2022.123229</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Filgueiras</surname>
							<given-names>M. F.</given-names>
						</name>
						<name>
							<surname>Lima</surname>
							<given-names>B. O.</given-names>
						</name>
						<name>
							<surname>Borges</surname>
							<given-names>E. M.</given-names>
						</name>
					</person-group>
					<year>2022</year>
					<article-title>A high-throughput, cheap, and green method for determination of ethanol in cachaça and vodka using 96-well-plate images</article-title>
					<source>Talanta</source>
					<volume>241</volume>
					<size units="pages">123229</size>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.talanta.2022.123229">https://doi.org/10.1016/j.talanta.2022.123229</ext-link>
				</element-citation>
			</ref>
			<ref id="B11">
				<mixed-citation>Fiske, C. H. and Subbarow, Y. 1925. The colorimetric determination of phosphorus. Journal of Biological Chemistry 66:375-400.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Fiske</surname>
							<given-names>C. H.</given-names>
						</name>
						<name>
							<surname>Subbarow</surname>
							<given-names>Y.</given-names>
						</name>
					</person-group>
					<year>1925</year>
					<article-title>The colorimetric determination of phosphorus</article-title>
					<source>Journal of Biological Chemistry</source>
					<volume>66</volume>
					<fpage>375</fpage>
					<lpage>400</lpage>
				</element-citation>
			</ref>
			<ref id="B12">
				<mixed-citation>Gliszczynska-Swiglo, A. and Rybicka, I. 2021. Fast and sensitive method for phosphorus determination in dairy products. Journal of Consumer Protection and Food Safety 16:213-218. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s00003-021-01329-x">https://doi.org/10.1007/s00003-021-01329-x</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Gliszczynska-Swiglo</surname>
							<given-names>A.</given-names>
						</name>
						<name>
							<surname>Rybicka</surname>
							<given-names>I.</given-names>
						</name>
					</person-group>
					<year>2021</year>
					<article-title>Fast and sensitive method for phosphorus determination in dairy products</article-title>
					<source>Journal of Consumer Protection and Food Safety</source>
					<volume>16</volume>
					<fpage>213</fpage>
					<lpage>218</lpage>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s00003-021-01329-x">https://doi.org/10.1007/s00003-021-01329-x</ext-link>
					</comment>
				</element-citation>
			</ref>
			<ref id="B13">
				<mixed-citation>Horwitz, W. and Albert, R. 2006. The Horwitz ratio (HorRat): A useful index of method performance with respect to precision. Journal of AOAC International 89:1095-1109. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1093/jaoac/89.4.1095">https://doi.org/10.1093/jaoac/89.4.1095</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Horwitz</surname>
							<given-names>W.</given-names>
						</name>
						<name>
							<surname>Albert</surname>
							<given-names>R.</given-names>
						</name>
					</person-group>
					<year>2006</year>
					<article-title>The Horwitz ratio (HorRat): A useful index of method performance with respect to precision</article-title>
					<source>Journal of AOAC International</source>
					<volume>89</volume>
					<fpage>1095</fpage>
					<lpage>1109</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1093/jaoac/89.4.1095">https://doi.org/10.1093/jaoac/89.4.1095</ext-link>
				</element-citation>
			</ref>
			<ref id="B14">
				<mixed-citation>McKie, V. A. and McCleary, B. V. 2016. A novel and rapid colorimetric method for measuring total phosphorus and phytic acid in foods and animal feeds. Journal of AOAC International 99:738-743. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.5740/jaoacint.16-0029">https://doi.org/10.5740/jaoacint.16-0029</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>McKie</surname>
							<given-names>V. A.</given-names>
						</name>
						<name>
							<surname>McCleary</surname>
							<given-names>B. V.</given-names>
						</name>
					</person-group>
					<year>2016</year>
					<article-title>A novel and rapid colorimetric method for measuring total phosphorus and phytic acid in foods and animal feeds</article-title>
					<source>Journal of AOAC International</source>
					<volume>99</volume>
					<fpage>738</fpage>
					<lpage>743</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.5740/jaoacint.16-0029">https://doi.org/10.5740/jaoacint.16-0029</ext-link>
				</element-citation>
			</ref>
			<ref id="B15">
				<mixed-citation>Mogashane, T. M.; Mapazi, O.; Motlatle, M. A.; Mokoena, L. and Tshilongo, J. 2025. A Review of recent developments in analytical methods for determination of phosphorus from environmental samples. Molecules 30:1001. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/molecules30051001">https://doi.org/10.3390/molecules30051001</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Mogashane</surname>
							<given-names>T. M.</given-names>
						</name>
						<name>
							<surname>Mapazi</surname>
							<given-names>O.</given-names>
						</name>
						<name>
							<surname>Motlatle</surname>
							<given-names>M. A.</given-names>
						</name>
						<name>
							<surname>Mokoena</surname>
							<given-names>L.</given-names>
						</name>
						<name>
							<surname>Tshilongo</surname>
							<given-names>J.</given-names>
						</name>
					</person-group>
					<year>2025</year>
					<article-title>A Review of recent developments in analytical methods for determination of phosphorus from environmental samples</article-title>
					<source>Molecules</source>
					<volume>30</volume>
					<size units="pages">1001</size>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/molecules30051001">https://doi.org/10.3390/molecules30051001</ext-link>
					</comment>
				</element-citation>
			</ref>
			<ref id="B16">
				<mixed-citation>Moonrungsee, N.; Pencharee, S. and Jakmunee, J. 2015. Colorimetric analyzer based on mobile phone camera for determination of available phosphorus in soil. Talanta 136:204-209. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.talanta.2015.01.024">https://doi.org/10.1016/j.talanta.2015.01.024</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Moonrungsee</surname>
							<given-names>N.</given-names>
						</name>
						<name>
							<surname>Pencharee</surname>
							<given-names>S.</given-names>
						</name>
						<name>
							<surname>Jakmunee</surname>
							<given-names>J.</given-names>
						</name>
					</person-group>
					<year>2015</year>
					<article-title>Colorimetric analyzer based on mobile phone camera for determination of available phosphorus in soil</article-title>
					<source>Talanta</source>
					<volume>136</volume>
					<fpage>204</fpage>
					<lpage>209</lpage>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.talanta.2015.01.024">https://doi.org/10.1016/j.talanta.2015.01.024</ext-link>
					</comment>
				</element-citation>
			</ref>
			<ref id="B17">
				<mixed-citation>Palma, M. N. N.; Rocha, G. C.; Valadares Filho, S. C. and Detmann, E. 2015. Evaluation of acid digestion procedures to estimate mineral contents in materials from animal trials. Asian-Australasian Journal of Animal Sciences 28:1624-1628. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.5713/ajas.15.0068">https://doi.org/10.5713/ajas.15.0068</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Palma</surname>
							<given-names>M. N. N.</given-names>
						</name>
						<name>
							<surname>Rocha</surname>
							<given-names>G. C.</given-names>
						</name>
						<name>
							<surname>Valadares</surname>
							<given-names>S. C.</given-names>
							<suffix>Filho</suffix>
						</name>
						<name>
							<surname>Detmann</surname>
							<given-names>E.</given-names>
						</name>
					</person-group>
					<year>2015</year>
					<article-title>Evaluation of acid digestion procedures to estimate mineral contents in materials from animal trials</article-title>
					<source>Asian-Australasian Journal of Animal Sciences</source>
					<volume>28</volume>
					<fpage>1624</fpage>
					<lpage>1628</lpage>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.5713/ajas.15.0068">https://doi.org/10.5713/ajas.15.0068</ext-link>
					</comment>
				</element-citation>
			</ref>
			<ref id="B18">
				<mixed-citation>Pulliainen, T. K. and Wallin, H. C. 1996. Determination of total phosphorus in foods by colorimetry: Summary of NMKL Collaborative study. Journal of AOAC International 79:1408-1410. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1093/jaoac/79.6.1408">https://doi.org/10.1093/jaoac/79.6.1408</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Pulliainen</surname>
							<given-names>T. K.</given-names>
						</name>
						<name>
							<surname>Wallin</surname>
							<given-names>H. C.</given-names>
						</name>
					</person-group>
					<year>1996</year>
					<article-title>Determination of total phosphorus in foods by colorimetry: Summary of NMKL Collaborative study</article-title>
					<source>Journal of AOAC International</source>
					<volume>79</volume>
					<fpage>1408</fpage>
					<lpage>1410</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1093/jaoac/79.6.1408">https://doi.org/10.1093/jaoac/79.6.1408</ext-link>
				</element-citation>
			</ref>
			<ref id="B19">
				<mixed-citation>Santos, I. C.; Schlesner, S. K.; Moraes, D. P.; Fereira, D. F.; Voss, M.; Giacomelli, S. R. and Barin, J. S. 2023. Smartphone-based rapid and low-cost method for the determination of eugenol content of clove essential oil. Ciência Rural 53:e20220498. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1590/0103-8478cr20220498">https://doi.org/10.1590/0103-8478cr20220498</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Santos</surname>
							<given-names>I. C.</given-names>
						</name>
						<name>
							<surname>Schlesner</surname>
							<given-names>S. K.</given-names>
						</name>
						<name>
							<surname>Moraes</surname>
							<given-names>D. P.</given-names>
						</name>
						<name>
							<surname>Fereira</surname>
							<given-names>D. F.</given-names>
						</name>
						<name>
							<surname>Voss</surname>
							<given-names>M.</given-names>
						</name>
						<name>
							<surname>Giacomelli</surname>
							<given-names>S. R.</given-names>
						</name>
						<name>
							<surname>Barin</surname>
							<given-names>J. S.</given-names>
						</name>
					</person-group>
					<year>2023</year>
					<article-title>Smartphone-based rapid and low-cost method for the determination of eugenol content of clove essential oil</article-title>
					<source>Ciência Rural</source>
					<volume>53</volume>
					<elocation-id>e20220498</elocation-id>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1590/0103-8478cr20220498">https://doi.org/10.1590/0103-8478cr20220498</ext-link>
				</element-citation>
			</ref>
			<ref id="B20">
				<mixed-citation>Schneider, C. A.; Rasband, W. S. and Eliceiri, K. W. 2012. NIH Image to ImageJ: 25 years of image analysis. Nature Methods 9:671-675. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1038/nmeth.2089">https://doi.org/10.1038/nmeth.2089</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Schneider</surname>
							<given-names>C. A.</given-names>
						</name>
						<name>
							<surname>Rasband</surname>
							<given-names>W. S.</given-names>
						</name>
						<name>
							<surname>Eliceiri</surname>
							<given-names>K. W.</given-names>
						</name>
					</person-group>
					<year>2012</year>
					<article-title>NIH Image to ImageJ: 25 years of image analysis</article-title>
					<source>Nature Methods</source>
					<volume>9</volume>
					<fpage>671</fpage>
					<lpage>675</lpage>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1038/nmeth.2089">https://doi.org/10.1038/nmeth.2089</ext-link>
					</comment>
				</element-citation>
			</ref>
			<ref id="B21">
				<mixed-citation>Suttle, F. S. 2010. The mineral nutrition of livestock. 4th ed. CABI, Penicuik, UK.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>Suttle</surname>
							<given-names>F. S.</given-names>
						</name>
					</person-group>
					<year>2010</year>
					<source>The mineral nutrition of livestock</source>
					<edition>4th</edition>
					<publisher-name>CABI</publisher-name>
					<publisher-loc>Penicuik, UK</publisher-loc>
				</element-citation>
			</ref>
			<ref id="B22">
				<mixed-citation>Thomas Sims, J. and Sharpley, A. N. (eds.). 2005. Phosphorus: agriculture and the environment. American Society of Agronomy, Crop Science Society of America, Soil Science Society of America, Madison, WI. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.2134/agronmonogr46">https://doi.org/10.2134/agronmonogr46</ext-link>
				</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="editor">
						<name>
							<surname>Thomas Sims</surname>
							<given-names>J.</given-names>
						</name>
						<name>
							<surname>Sharpley</surname>
							<given-names>A. N.</given-names>
						</name>
						<role>eds</role>
					</person-group>
					<year>2005</year>
					<source>Phosphorus: agriculture and the environment</source>
					<publisher-name>American Society of Agronomy, Crop Science Society of America, Soil Science Society of America</publisher-name>
					<publisher-loc>Madison, WI</publisher-loc>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.2134/agronmonogr46">https://doi.org/10.2134/agronmonogr46</ext-link>
				</element-citation>
			</ref>
			<ref id="B23">
				<mixed-citation>Vargas-Muñoz, M. A.; Morales, J.; Cerdà, V.; Ferrer, L. and Palacio, E. 2023. Paper sensor-based method using a portable 3D-printed platform and smartphone-assisted colorimetric detection for ammonia and sulfide monitoring in anaerobic digesters and wastewater. Microchemical Journal 188:108469. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.microc.2023.108469">https://doi.org/10.1016/j.microc.2023.108469</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Vargas-Muñoz</surname>
							<given-names>M. A.</given-names>
						</name>
						<name>
							<surname>Morales</surname>
							<given-names>J.</given-names>
						</name>
						<name>
							<surname>Cerdà</surname>
							<given-names>V.</given-names>
						</name>
						<name>
							<surname>Ferrer</surname>
							<given-names>L.</given-names>
						</name>
						<name>
							<surname>Palacio</surname>
							<given-names>E.</given-names>
						</name>
					</person-group>
					<year>2023</year>
					<article-title>Paper sensor-based method using a portable 3D-printed platform and smartphone-assisted colorimetric detection for ammonia and sulfide monitoring in anaerobic digesters and wastewater</article-title>
					<source>Microchemical Journal</source>
					<volume>188</volume>
					<size units="pages">108469</size>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.microc.2023.108469">https://doi.org/10.1016/j.microc.2023.108469</ext-link>
					</comment>
				</element-citation>
			</ref>
			<ref id="B24">
				<mixed-citation>Wongniramaikul, W. and Choodum, A. 2017. Synthesis of polymer sensor for detection of phosphate in water. International Journal of Chemical Engineering and Applications 8:221-225.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Wongniramaikul</surname>
							<given-names>W.</given-names>
						</name>
						<name>
							<surname>Choodum</surname>
							<given-names>A.</given-names>
						</name>
					</person-group>
					<year>2017</year>
					<article-title>Synthesis of polymer sensor for detection of phosphate in water</article-title>
					<source>International Journal of Chemical Engineering and Applications</source>
					<volume>8</volume>
					<fpage>221</fpage>
					<lpage>225</lpage>
				</element-citation>
			</ref>
			<ref id="B25">
				<mixed-citation>Yang, C.-X.; Sun, X.-Y.; Liu, B. and Lian, H.-T. 2007. Determination of total phosphorus in water sample by digital imaging colorimetry. Chinese Journal of Analytical Chemistry 35:850-853. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/S1872-2040(07)60059-0">https://doi.org/10.1016/S1872-2040(07)60059-0</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Yang</surname>
							<given-names>C.-X.</given-names>
						</name>
						<name>
							<surname>Sun</surname>
							<given-names>X.-Y.</given-names>
						</name>
						<name>
							<surname>Liu</surname>
							<given-names>B.</given-names>
						</name>
						<name>
							<surname>Lian</surname>
							<given-names>H.-T.</given-names>
						</name>
					</person-group>
					<year>2007</year>
					<article-title>Determination of total phosphorus in water sample by digital imaging colorimetry</article-title>
					<source>Chinese Journal of Analytical Chemistry</source>
					<volume>35</volume>
					<fpage>850</fpage>
					<lpage>853</lpage>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/S1872-2040(07)60059-0">https://doi.org/10.1016/S1872-2040(07)60059-0</ext-link>
					</comment>
				</element-citation>
			</ref>
		</ref-list>
		<fn-group>
			<fn fn-type="data-availability" specific-use="data-available-upon-request">
				<label>Data availability:</label>
				<p> The dataset supporting the results of this study is available upon request.</p>
			</fn>
			<fn fn-type="supplementary-material" id="supplfn">
				<label>Supplementary material</label>
				<p> The supplementary material of this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.rbz.org.br/wp-content/uploads/articles_xml/1806-9290-rbz-55-e20250130/1806-9290-rbz-55-e20250130-suppl01.xlsx">https://www.rbz.org.br/wp-content/uploads/articles_xml/1806-9290-rbz-55-e20250130/1806-9290-rbz-55-e20250130-suppl01.xlsx</ext-link>
				</p>
			</fn>
			<fn fn-type="financial-disclosure">
				<label>Financial support:</label>
				<p> This research received financial support from PROPPG/UFRRJ (23083.046986/2023-91), Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq; 312920/2023-7), and Fundação Carlos Chagas Filho de Amparo à Pesquisa do Estado do Rio de Janeiro (FAPERJ; 200.124/2023). Scholarships from Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) and PROPPG/UFRRJ were awarded to Lima, L. B. and Silva, C. G., respectively.</p>
			</fn>
		</fn-group>
	</back>
</article>